396
REVISIONS
*The manual number is given on the bottom left of the back cover.
Print Date *Manual Number Revision
May 2004 IB(NA)-0600193ENG-A
First edition
Aug. 2004 IB(NA)-0600193ENG-B
FR-F740 - 02600 to 03610 - EC
Pr.299 Rotation direction detection selection at restarting
Oct. 2004 IB(NA)-0600193ENG-C
FR-F740 - 04320 to 12120 - EC
Jun. 2005 IB(NA)-0600193ENG-D
Partial modification
Panel cut dimension of heatsink protrusion
May 2006 IB(NA)-0600193ENG-E
Partial modification
Panel cut dimension of heatsink protrusion
Pr. 539 Modbus-RTU communication check time interval
Voltage/current input switch
Jul. 2008 IB(NA)-0600193ENG-F
Additional explanation to "Causes and corrective actions"
Addition of setting values "10" and 11" to Pr. 495 Remote output selection
Sep. 2009 IB(NA)-0600193ENG-G
Pr. 29 setting value "6", Pr. 30 setting value "10", "11", "20", "21", Pr. 59 setting
value "11 ", "12 ", "13 ", Pr.128 setting value "110", "111", "120", "121",
Pr.167 setting value "10", "11", Pr. 261 setting value "21", "22",
Pr.522, Pr.553, Pr.554, Pr.653, Pr.654, Pr.799, C42 (Pr.934), C43 (Pr.934), C44
(Pr.935), C45 (Pr.935)
DC feeding operation permission signal (X70), DC feeding cancel signal
(X71), PID integral value reset signal (X72)
PID deviation limit signal (Y48), Pulse output of output power signal (Y79),
DC feeding signal (Y85)
Pr.153 setting range "0 to 10s"
5.5 Check first when you have a trouble
Apr. 2012 IB(NA)-0600193ENG-H
Pr. 147, Pr. 296, Pr. 297, Pr. 390, Pr. 414, Pr. 415, Pr. 498, Pr.502, Pr.505 to Pr.515,
Pr.561, Pr.665, Pr.726 to Pr.729, Pr.753 to Pr. 769, Pr.774 to Pr. 779, Pr.826 to Pr.
865, Pr. 870, Pr. 986, Pr. 997, Pr. 999
Setting value of Pr. 30, Pr. 52, Pr. 54, Pr. 128, Pr. 158, Pr. 178 to Pr. 189, Pr. 190 to
Pr. 196, Pr. 331, Pr. 332, Pr. 549, Pr. 573
Option connector 2
Easy operation mode setting
Function enhancement of Mitsubishi inverter protocol/Modbus-RTU protocol
communication
BACnet MS/TP protocol
PLC function
Initial value change list function
Protective function (LOCD, E.2, E.OP2, E.PCH, E.LCI)
Addition
Addition
Addition
Addition
Addition
Addition
Partial modification
Addition
IB(NA)-0600193ENG-H

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi F700 Series and is the answer not in the manual?

Mitsubishi F700 Series Specifications

General IconGeneral
Humidity95% RH or less (non-condensing)
Control MethodV/F control
Protection FeaturesOvercurrent, overvoltage, undervoltage, overheat, short circuit
Communication OptionsRS-485
Operating Temperature-10°C to +50°C
Storage Temperature-20°C to +65°C
AltitudeUp to 1000m above sea level
Overload Capacity150% for 60 seconds
Cooling MethodForced air cooling
Power Range0.75 to 630 kW (1 to 845 hp)
Output Voltage3-phase 200 to 240 VAC, 380 to 500 VAC (matching input voltage)