Mitsubishi F700 Series User Manual

Mitsubishi F700 Series
408 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #81 background imageLoading...
Page #81 background image
70
4.22.6 Initiating a fault (Pr.997)............................................................................................................................................ 304
4.22.7 Setting multiple parameters as a batch (Pr.999)..................................................................................................... 305
4.23 Setting from the parameter unit, operation panel 311
4.23.1 PU display language selection (Pr. 145) ................................................................................................................. 311
4.23.2 Setting dial potentiometer mode/key lock selection (Pr. 161)................................................................................. 311
4.23.3 Buzzer control (Pr. 990)............................................................................................................................................ 313
4.23.4 PU contrast adjustment (Pr. 991)............................................................................................................................. 313
4.24 Setting of FR-PU07-01 314
4.24.1 PID display bias/gain setting menu.......................................................................................................................... 315
4.24.2 Unit selection for the PID parameter/PID monitored items (Pr. 759) ..................................................................... 316
4.24.3 PID set point direct setting menu............................................................................................................................. 317
4.24.4 3-line monitor selection (Pr. 774 to Pr.776) ............................................................................................................. 318
4.25 Parameter clear 319
4.26 All parameter clear 320
4.27 Parameter copy and parameter verification 321
4.27.1 Parameter copy ........................................................................................................................................................ 321
4.27.2 Parameter verification............................................................................................................................................... 322
4.28 Initial value change list 323
4.29 Check and clear of the faults history 324

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi F700 Series and is the answer not in the manual?

Mitsubishi F700 Series Specifications

General IconGeneral
Humidity95% RH or less (non-condensing)
Control MethodV/F control
Protection FeaturesOvercurrent, overvoltage, undervoltage, overheat, short circuit
Communication OptionsRS-485
Operating Temperature-10°C to +50°C
Storage Temperature-20°C to +65°C
AltitudeUp to 1000m above sea level
Overload Capacity150% for 60 seconds
Cooling MethodForced air cooling
Power Range0.75 to 630 kW (1 to 845 hp)
Output Voltage3-phase 200 to 240 VAC, 380 to 500 VAC (matching input voltage)