M800S/M80/E80 Series Connection and Setup Manual
10 Connection of Remote I/O Unit
315
IB-1501269-J
(a) Connecting with the voltage input signal
- Use the twisted cable with shield to reduce the influence of noise.
- Connect the shield to FG pin of AI connector. Ground the machine side, too.
- Do not connect or disconnect the cables between units while the power is ON.