M800S/M80/E80 Series Connection and Setup Manual
4 General Specifications
29
IB-1501269-J
(Note 1) "Short term" means roughly within one month.
(Note 2) The current consumption of the keyboard unit and the operation panel I/O unit (control section) are included in
that of the control unit. Current consumption for the I/O circuit needs to be separately calculated based on the
number of points used and its load.
(Note 3) For the heating value of the I/O circuit, calculate with the number of points used.
(Note 4) For the whole NC system, consider the characteristics of the drive units when the altitude is more than 1000
meters above sea level. Refer to the manual of drive unit for details.
(Note 5) 24V power input is not required for FCU8-KB931/KB941.
(Note 6) Current consumption for the I/O circuit needs to be separately calculated based on the number of points used
and its load.
Item
Unit name Keyboard unit Operation panel I/O unit Machine operation panel
Type
FCU8-KB041/KB046 : (10.4-type)
FCU8-KB047 : (10.4-type/vertical
arrangement)
FCU8-KB048 : (10.4-type)
FCU8-KB083 : (15-type/vertical
arrangement)
FCU8-DX731
FCU8-DX750
FCU8-DX760
FCU8-DX761
FCU8-DX834
FCU8-KB921/KB922/
KB925
FCU8-KB923/KB924/
KB926
FCU8-KB931/KB941
General
Specifications
Ambient
temperature
During
operation
0 to 58°C
During
storage
-20 to 60°C
Ambient
humidity
Long term 10 to 75% RH (with no dew condensation)
Short term 10 to 95% RH (with no dew condensation) (Note 1)
Vibration resistance
4.9m/s
2
or less
Shock resistance
29.4m/s
2
or less
Working atmosphere No corrosive gases, dust or oil mist
Altitude
Operation/Storage: 1000 meters or less above sea level,
Transportation: 13000 meters or less above sea level
Power supply voltage
5VDC 5VDC/3.3VDC
24VDC 24VDC (Note 5)
(Supply from Control Unit)
Current consumption - (Note 2)
24V 0.3A
(Note 6)
0.3A (Note 5)
Maximum
heating value
(W) 1 4 (Note 3) 8 (Note 3) 7.2
Mass (kg)
FCU8-KB041/KB046 : 0.8
FCU8-KB047 : 1.3
FCU8-KB048 : 1.4
FCU8-KB083 : 1.5
FCU8-DX731 :
0.3
FCU8-DX750 :
0.4
FCU8-DX760 :
0.5
FCU8-DX761 :
0.5
0.4
FCU8-KB921/KB922/
KB925 :
1.1
FCU8-KB923/KB924/
KB926 :
1.2
FCU8-KB931/KB941 :
0.5
Outline
dimension
W×H
(mm)
FCU8-KB041/KB046 : 140×220
FCU8-KB047 : 290×160
FCU8-KB048 : 230×220
FCU8-KB083 : 400×140
116×179
FCU8-KB921/KB922/
KB925 :
260×140
FCU8-KB923/KB924/
KB926 :
290×140
FCU8-KB931/KB941 :
140×140