5 - 135
Chapter 5 Data Used for Positioning Control
Storage buffer
memory address
Reading the monitor value
Default
value
QD77MS2
QD77MS4
QD77MS16
Monitoring is carried out with a decimal display.
R
Monitor
value
Decimal integer
value
Unit conversion table
A
ctual
value
Unit conversion
R
10
m
)
)
Md.32
Target value
Md.32
inch
degree
PLS
-1
-5
-5
0
m
Unit
m
0
818+100n
819+100n
2418+100n
2419+100n
0000H
820+100n
821+100n
2420+100n
2421+100n
Monitoring is carried out with a hexadecimal display.
A B C D
A
B
C
D
E F
G
H
E
R
F
G
H
b15 b12 b4 b0b8
EF
G
H
b31 b28 b20 b16b24
ABCD
Monitor
value
Low-order buffer memory Example) 820
High-order buffer memory Example) 821
Sorting
Decimal integer
value
Converted from
hexadecimal to decimal
m
inch
degree
PLS
-1
-5
-5
0
m
Unit
mm/min
inch/min
degree/min
m
-2
-3
-3
0PLS/s
Unit
Unit conversion table
Unit conversion
Actual value
(High-order buffer memory) (Low-order buffer memory)
R 10
m
Unit conversion table
Target speed
Md.33
)
)
Md.33
)
Md.34
Movement amount after
near-point dog ON
Md.34
)
: When " Pr.83 Speed
control 10 x multiplier
setting for degree axis"
is valid : "-2"
0000H
824+100n
825+100n
2424+100n
2425+100n
n: Axis No.-1