5 - 174 
Chapter 5  Data Used for Positioning Control
 
 
 
Setting item  Setting details 
 
 
Simultaneous starting axis 
start data No. (axis 1 start 
data No.) 
QD77MS2 QD77MS4
 
•
  Use these data items to specify an axis 1 start data No. for 
each axis that has to start simultaneously. 
•
  Set "0" to any axis that should not start simultaneously. 
 
 
 
 
 
Cd.30
 
Simultaneous starting own 
axis start data No.  
QD77MS16
 
•
  Use these data items to specify a start data No. of own axis at 
multiple axes simultaneous starting. 
Fetch: At start
 
 
 
 
 
Simultaneous starting axis 
start data No. (axis 2 start 
data No.) 
QD77MS2 QD77MS4
 
•
  Use these data items to specify an axis 2 start data No. for 
each axis that has to start simultaneously. 
•
  Set "0" to any axis that should not start simultaneously. 
 
 
 
 
 
Cd.31
 
Simultaneous starting axis 
start data No.1 
QD77MS16
 
•
  Use these data items to specify a start data No.1 for each axis 
that has to start simultaneously. 
Fetch: At start
 
 
 
 
 
Simultaneous starting axis 
start data No. (axis 3 start 
data No.) 
QD77MS4
 
•
  Use these data items to specify an axis 3 start data No. for 
each axis that has to start simultaneously. 
•
  Set "0" to any axis that should not start simultaneously. 
 
 
 
 
 
Cd.32
 
Simultaneous starting axis 
start data No.2 
QD77MS16
 
•
  Use these data items to specify a start data No.2 for each axis 
that has to start simultaneously. 
 
Note) For 2 axis simultaneous starting, the axis setting is not 
required. 
(Setting value is ignored.) 
Fetch: At start
 
 
 
 
 
 
 
 
 
Simultaneous starting axis 
start data No. (axis 4 start 
data No.) 
QD77MS4
 
•
  Use these data items to specify an axis 4 start data No. for 
each axis that has to start simultaneously. 
•
  Set "0" to any axis that should not start simultaneously. 
 
 
 
 
 
Cd.33
 
Simultaneous starting axis 
start data No.3 
QD77MS16
 
•
  Use these data items to specify a start data No.3 for each axis 
that has to start simultaneously. 
 
Note) For 2 axis simultaneous starting and 3 axis simultaneous 
starting, the axis setting is not required. 
(Setting value is ignored.) 
Fetch: At start
 
 
 
 
 
 
 
 
 
Cd.34
Step mode
 
•
 To perform a step operation, use this data item to specify the units by which the 
stepping should be performed. 
 
Fetch cycle: At start