5 - 193
Chapter 5 Data Used for Positioning Control
Storage buffer
memory address
Setting value
Default
value
QD77MS2
QD77MS4
QD77MS16
Set with a decimal.
Setting
value
K
Axis stop
1 : Axis stop requested
Other than 1: Axis stop not requested
0 30100+10n
0 30101+10n
Set with a decimal.
Setting
value
K
Forward run JOG start/Reverse run JOG start
1 : JOG started
Other than 1: JOG not started
0 30102+10n
Set with a decimal.
Setting
value
K
Execution prohibition flag
1 : During execution prohibition
Other than 1: Not during execution prohibition
0 30103+10n
n: Axis No.-1