16 - 40
Chapter 16 Troubleshooting
Classification
of errors
Error
code
Error name Error Operation status at error occurrence
950
Acceleration time 1
setting error
The set value of the detailed parameter 2
"Acceleration time 1" is outside the setting
range.
951
Acceleration time 2
setting error
The set value of the detailed parameter 2
"Acceleration time 2" is outside the setting
range.
952
Acceleration time 3
setting error
The set value of the detailed parameter 2
"Acceleration time 3" is outside the setting
range.
953
Deceleration time 1
setting error
The set value of the detailed parameter 2
"Deceleration time 1" is outside the setting
range.
954
Deceleration time 2
setting error
The set value of the detailed parameter 2
"Deceleration time 2" is outside the setting
range.
955
Deceleration time 3
setting error
The set value of the detailed parameter 2
"Deceleration time 3" is outside the setting
range.
When the PLC READY signal [Y0] is turned
from OFF to ON :The QD77 READY signal
[X0] is not turned ON.
At start : The system does not
operate.
During operation : The system stops with the
setting (deceleration
stop/sudden stop) of the
detailed parameter 2
sudden stop selection
(stop group 3).
(Note that the deceleration
stop only occurs during the
manual pulse generator
operation.)