A – not selected – Cabin door will be open in the fire station when fire
program are active.
selected – Cabin door will closing automatically after 60 sec in the fire
station when fire program are active.
B – not selected –
selected –
C – Enable service until arrival stopping zone.
D – not selected – First travel after service travel must be confirmed with
call
selected – If cabin are in the station, cabin door will open after service
travel
E – not selected – without UCM status reset after service travel
selected – UCM status reset after service travel
F – not selected – First travel after service travel must be confirmed with
call
selected – If cabin are in the station, cabin door will open after service
travel
G – reserved
H – not selected – Enable reset with button or terminal.
selected – Disable reset with button or terminal.
Enterence to service drive
When function service travel enterance are active (FI-326), elevator came
to seted station and start drive with low speed
Distance to service drive
Descent time/space for entering on cabin roof (service travel).
T-21 station bellow T-22 time/space.
Defining how many impulses is 100 mm.
When parameter is present, then all other menus for positioning are
showed in mm.
Set protection password level 1 for locking menu.
If password is seted, on system booting must be entered password.
If you don’t use keypad more then 10 min. system is automatically locked,
to disable password put factory value 0000.