LC100 Instruction manual
4/6 Parameters
2/12 Call processing
Type B
B-15
Parking stop 2
0-A1
Setting the parking stop 2.
0 Not activated parking program is not active.
1-A1 Parking floor.
After the time set in the parameter B-16 expires elevator goes to parking stop
and does not open the doors.
B-16
Time for parking 2
0-41min 40s
Time for parking for parking zone 2.
B-17
Landing call disable
0-41min 40s
Parameter is used to disable landing and cabin calls. Function for
disabling the calls is on the input with function FI-296.
Parameter B-17 is used to define the condition for calls disabling. How
to set the B-17 parameter is explained in configurating disable calls
manual.
B-18
Cancel cabine Calls
0-1
Parameter is used to enable/disable cancle cabine calls.
If is enabled, when you press cabin call and you want cancel cabin
call just need press against the same cabin call and it will be canceled
and elevator will stop in first nearest station.
B-19
Fire program standard
0-3