EasyManua.ls Logo

MLC LC100 - Page 82

MLC LC100
148 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
82
LC100 Instruction manual
4/6 Parameters
2/12 Call processing
Type B
B-10
Fire stop zone 4
0-A1
Defining the floor for evacuation in case of fire program 3. Fire program 3 is
activated through the input with the function parameter FI-212.
Fire program 4 has lower priority than fire programs 3, 2 and 1.
B-11
False calls erasing
0-8
Erasing the false cabin calls:
0 Erasing the calls is disabled
1 Erasing the calls after first call
2 Erasing the calls after second call
3 Erasing the calls after third call
4 Erasing the calls after fourth call
5 Erasing the calls after fifth call
6 Erasing the calls after sixth call
7 Erasing the calls after seventh call
8 Erasing the calls after eight call
False call erasing: if there are many cabin calls, when the elevator stops at the floor and the landing doors are
not opened or there is no pasing through photocell this is called false call.
B-12
Parking program
1-2
Choosing the parking type program.
1. MASTER elevator decides which elevator is going to park. Parking stop
set on the master elevator is active for parking. In the parking stop there
is one elevator which is parked and proces only landing calls from that
stop and exits from the parking floor if there is more landing calls than free
elevators in multiplex.
2. In multiplex mode, each elevator separately make parking.
B-13
Parking stop 1
0-A1
Setting the parking stop 1.
0 Not activated parking program is not active.
1-A1 Parking floor.
After the time set in the parameter B-14 expires elevator goes to parking stop,
and does not open the doors.
B-14
Time for parking 1
0-41min 40s
Time for parking for parking zone 1.

Table of Contents