Appendix
10/05 AWB8230-1541GB
226
PNU RUN b031
= 10
Name Value range DS page User setting
C001
––
Digital input 1 – function 00: FWD: Clockwise rotating field 00 77
01: REV: Anticlockwise rotating field
02: CF1: Fixed frequency selection, bit 0
(LSB)
03: CF2: Fixed frequency selection, bit 1
04: CF2: Fixed frequency selection, bit 2
05: CF4: Fixed frequency selection, bit 3
(MSB)
06: JOG, jog mode
07: DB, DC braking
08: SET: Select second parameter set
09: 2CH: Second time ramp
11: FRS: Free run stop (free coasting,
= controller inhibit)
12: EXT: External fault message
13: USP: Unattended start protection
15: SFT: Parameter access inhibit
16: AT: change over to analog input OI
18: RST: Reset fault signal
19: PTC: PTC thermistor input (digital input
5 only)
20: STA: Three-wire control start signal
21: STP: Three-wire control stop signal
22: F/R: Three-wire control, direction of
rotation
23: PID: Disable PID control
24: PIDC: Reset integral component of PID
control
27: UP: Acceleration (motor potentiometer)
28: DWMN: Deceleration (motor
potentiometer)
29: UDC: Motor potentiometer, reset saved
value of motor potentiometer to 0 Hz
31: OPE: Operator keypad
50: ADD: Offset – add value from
PNU A145 to frequency reference
value.
51: F-TM: Digital input, mode: control
signal terminals preferred.
52: RDY: Inverter, reduce response time to
control signals
53: SP-SET: Second parameter set with
special functions
255:
-- (no function)
C201
––
Digital input 1 – function
(second parameter set)
Values a PNU C001 00 77