Troubleshooting Charts: Power-Up Failure 5-5
Power-Up Failure – Low LDO10 VCC_3.3 Voltage
Low LDO10 VCC_3.3 
Voltage
Measure Radio 
Current
Is Standby 
Current more 
than 15mA above 
Average
Board has a short, 
Replace VOCON
Yes
Inspect R6566 
Connection
Is R6566 
Soldered 
Properly
Correct R6566 
Soldering
Measure SW1 at 
R6542
3.3 < V < 3.9?
Proceed To Low 
VCC_SW_3.6 
Voltage Flow 
Chart
Likely MAKO 
Problem, Replace 
VOCON Board
No
No
Yes
No
Yes
Synopsis
This failure specifically refers to LDO10 
but this flow chart can be used to 
diagnose LDO9, lDO7, and LDO6. All 
LDOs mentioned above are fed from the 
same source and have very limited 
differences.  Please refer to schematic 
and theory of operation section for 
differences.