16
Remove shield, SH4.  
Measure RF levels at first 
preselector filter and 
compute filter loss.  
UHF2: Input side of C1935 
& output side of C1939.
Loss < 4
dB?
Check components 
and replace defective 
parts.
Autotune the radio.
No
Measure RF levels at LNA 
and compute LNA gain.
UHF2: Input side of C1931 
and output side of C1936.  
Gain about 
18 dB?
Check LNA:
Check DC bias voltages of 
U1932 at the base (pin 1) & 
collector (pin 3).
No
Is base voltage = 
0.787 V?  Collector 
voltage = 1.56 V?
Replace 
U1932
Is base voltage = 1.022 V?” 
Collector voltage = 
0.787 V?  Emitter 
voltage = 1.561 V?
Replace 
Q1922
Check DC input line voltages 
and visually inspect and 
replace defective 
components if needed.
No
Yes
No
Yes
Measure RF levels at second 
preselector filter and compute 
filter loss.
UHF2: input side of C1959 & 
output side of C1961
Loss < 4 
dB?
Check components 
and replace defective 
parts.
Autotune the radio.
No
Yes
Measure RF levels of the RF 
switch, U501, at the input to the 
mixer and compute loss.
UHF2: output side of C510 and 
input side of C511.
U501 loss 
< 1 dB?
8
Yes
No
Yes
Yes
Check DC bias voltages of 
Q1922 at the base (pin 2 or 
5), collector (pin 3) & emitter 
(pin 4).
Check digital logic 
to the RF switch 
and replace U501 if 
needed.
Remove shield, SH7. Measure 
RF levels at the filter and 
compute filter loss.  Output 
side of C1961 and output side 
of C510.
Filter Loss 
< 3 dB?
Visually inspect 
and replace 
components if 
necessary.
No
Yes
Note: RF Test frequency used:
VHF:   154.275 MHz
UHF1: 424.975 MHz
UHF2: 485.075 MHz
700:    769.0625 MHz
800:    860.0625 MHz
Measured with a high impedance probe for 
relative comparisons and troubleshooting only.
Actual S21 gain or loss may differ if the 
test point is not 50 ohms.