NPort 6000 Series Introduction
1-12
Power Requirements
Input Voltage:
AC Models: 100 to 240 VAC
DC Models:
±48 VDC (20 to 72 VDC, -20 to -72 VDC), 110 VDC (88 to 300 VDC)
Input Current:
AC Models:
140 mA @ 100 VAC (8 ports)
192 mA @ 100 VAC (16 ports)
285 mA @ 100 VAC (32 ports)
DC Models:
293 mA @ 48 VDC
200 mA @ 88 VDC
Alarm Contact:
Relay output with current-carrying capacity of 1 A @ 24 VDC
Power Line Protection:
1 kV burst (EN 61000-4-4: EFT/B), 0.5 kV surge (EN 61000-4-5)
Standards and Certifications
Safety:
UL 60950-1
EMC: 55022/24
EMI:
CISPR 22, FCC Part 15B Class A
EMS:
NPort 6600
-8/16/32:
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
IEC 61000-4-4 EFT: Power 1 kV; Signal 0.5 kV
IEC 61000-4-5 Surge: Power 2kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz, 3 V/m; Signal: 3 V/m
IEC 61000-4-8 PFMF
IEC 61000-4-11 DIPs
NPort 6600 48V models:
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
IEC 61000-4-4 EFT: Power 1 kV; Signal 0.5 kV
IEC 61000-4-5 Surge: Power 1 kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz, 3 V/m; Signal: 3 V/m
IEC 61000-4-8 PFMF
NPort 6650 HV models:
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
IEC 61000-4-4 EFT: Power 4 kV; Signal 2 kV
IEC 61000-4-5 Surge: Power 2 kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz, 3 V/m; Signal: 3 V/m
IEC 61000-4-8 PFMF
Freefall:
IEC-68-2-6, IEC-68-2-34, IEC-68-2-32
Vibration:
IEC-68-2-6, IEC-68-2-34
Green Product:
RoHS, CRoHS, WEEE
Reliability
Alert Tools:
Built-in buzzer and RTC (real-time clock)
Automatic Reboot Trigger:
Built-in WDT (watchdog timer)