OnCell G3100 Series Cellular Network Settings
Option Description
Local Verify the ID against the OnCell G3100 password. The user name for the
G3100 is fixed to “admin.”
None Authentication is not required.
Phone number: Use this field to configure the number used to dial out.
Initial string: Use this field to configure the initial string that the IP gateway will use to establish the
connection.
Connection control Connect Rule Disconnect Rule GSM
Always on/None Always on after power on None Trunk
Periodically
connect/inactivity time
Periodically connect (based on the
connection interval setting) to GSM
after power on.
Inactivity time is up Trunk
Remote host fail/remote
host recovered
Remote Ethernet host has failed. The
OnCell G3100 will keep pinging the
remote host over the Ethernet every 3
seconds after powering on. After failing
to connect 5 times in a row, the data
from the serial device will be sent
through the GSM connection.
When the remote
normal, data will revert
to being sent over
Ethernet after 5
continuous successful
pings.
Backup
Connection interval (default= 5 min): The time interval of the periodically connect function.
Ping remote host: Key in the IP address or Domain name of the remote host.
GPRS or GPRS/EDGE/UMTS/HSPA Operation Mode
TCP/IP compression (default=Disable): The setting of this field depend on whether or not the remote
user’s application requests compression.
Inactivity time (default=0 ms): This field specifies the idle time setting for auto-disconnection. A setting of
0 ms will cause the port to remain connected even if idle.
Link quality report (default=Disable): Setting this field to
Enable allows the OnCell G3100 to check the
PPP connection status with a base station that supports link monitoring.