OnCell G3100 Series Using the Web Console
6-12
GuaranLink Check Settings
ISP initial connection check (default=Disable): This function ensures that the OnCell can establish a
connection with an ISP after it reboots.
Cellular connection alive check (default=Disable): Some ISPs may disable the connection if no data is
transmitted in a specific period of time. This function ensures that the cellular connection will be kept alive even
if no data is transmitted for a period of time by performing the check action of DNS lookup or ping action of
DNS/Ping remote host 1 or DNS/Ping remote host 2. If the check action fails after the retry count number
specified in “Cellular connection alive check retry count”, the OnCell will re-establish a connection with the ISP.
Cellular connection alive check interval (min) (default=5 min): This setting specifies the idle time
before GuaranLink performs the check action.
Cellular connection alive check retry count (default=3 sec): This setting specifies the number of
attempts to reach the remote target(s) before the OnCell re-establishes a connection.
Packet-level connection check (default=Disable): This function checks if the cellular network can be
accessed by performing the check action of lookup DNS or ping action of DNS/Ping remote host 1 or DNS/Ping
remote host 2. If the check action fails after the retry count number specified in “Packet-level connection check
retry count.” the OnCell will re-establish a connection with ISP.
Packet-level connection check action (default=DNS and PING): This setting specifies whether the check
action is successful when both of the DNS lookup and the ping action succeed, or if it is successful even if only
one of them succeed.
Packet-level connection check interval (min) (default=5 min): This setting specifies the interval
between two check actions.
Packet-level connection check retry count (default=3 sec): This setting specifies the number of
attempts to reach the remote target(s) before the OnCell re-establishes a connection.

Table of Contents

Other manuals for Moxa Technologies OnCell G3100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Moxa Technologies OnCell G3100 and is the answer not in the manual?

Moxa Technologies OnCell G3100 Specifications

General IconGeneral
BrandMoxa Technologies
ModelOnCell G3100
CategoryGateway
LanguageEnglish

Related product manuals