EasyManua.ls Logo

NETGEAR GS752TP - Page 165

NETGEAR GS752TP
275 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Managing Device Security
165
GS752TP, GS728TP, and GS728TPP Gigabit Smart Switches
3. In the Connection Timeout field, specify the maximum number of seconds allowed to
establish a TCP connection between the switch and the TACACS+ server.
The valid range is 1–30 seconds. The default is 5 seconds.
4. Click APPLY to update the switch with the
TACACS+ Accounting server settings.
TACACS+ Server Configuration
Use the TACACS+ Server Configuration screen to configure up to five TACACS+ servers
with which the switch can communicate.
To configure TACACS+ server settings:
1. Select Security
Management Security > TACACS+ TACACS+ Server Configuration
link.
The following screen displays:
2. In the TACACS+ Server field, enter the IP address of the server to add
3. In the Priority field, specify the order in which the TACACS+ servers are used.
A value of 0 is the highest priority
.
4. In the Port field, specify the authentication port number through which the TACACS+
session occurs.
The default is port 49, and the range is 0–65535.
5. In the Key String field, specify the authentication and encryption key for TACACS+
communications between the switch and the
TACACS+ server.
This key must match the encryption used on the TACACS+ server. The valid range is
0–128 characters.