Table 2. Menu Mode Navigational Buttons
To edit the Menu
To navigate through
the SELECTIONS
To choose what is on
the display
To navigate between
menus
Press SELECT.
Two top characters
blink.
Press NEXT.
Continue pressing
NEXT to view all
selections.
Press SELECT.
blinking characters
become static.
Press NEXT or PREV.
Advance - press NEXT.
Previous - press PREV.
Table 3. Programming Initial Setup Menu
Display Display Selections
UC 0
USAGE CLASS
SELECTIONS
0 - No Usage Class set.
1 - Single Family residential up to four units.
2 - Multi-family, hotel, etc.
3 - Industrial use, not for general public.
4 - Guarded and monitored facility, not for general public.
SELECTIONS
0 - No handing set. Gate will not move until handing is set.
Looking at the gate from the secure side, choose:
L - If the gate slides open to the left.
R - If the gate slides open to the right.
WT 0
GATE WEIGHT (LB)
SELECTIONS
0 - Gate weight not set.
SlideSmart DC HD25 and HD30
1 - Gate weight: 0 – 700lbs (0 – 318Kg)
2 - Gate weight: 701 – 1400lbs (318 – 635Kg)
3 - Gate weight: 1401 – 2100lbs (635 – 953Kg)
4 - Gate weight: Over 2100lbs (over 953Kg)
Once gate weight is set, program Sensor1, Sensor2, Sensor3.
S1 0
SENSOR #1 TYPE
0 - disabled
1 - (NOT USED)
2 - (EYE CLOSE)
3 - (EDGE CLOSE
4 - (EYE OPEN)
5 - (EDGE OPEN)
6 - (EDGE BOTH) (Swing Gates only)
7 - (EYE BOTH) (solo Slide Gates only)
S2 0
SENSOR #2 TYPE
Same as Sensor 1
S3 0
SENSOR #3 TYPE
Same as Sensor 1
INSTALLATION
SlideSmart HD Programming and Operations
2424