DISPLAY AND MENU OPTIONS
ENABLING FIRE DEPARTMENT OVERRIDE
Many counties and cities require a Fire Department
override system for gate operators. The fire
department’s alert system is a separate unit that
must be connected to the Smart DC Controller.
FIRE DEPARTMENT OPEN option must be
properly congured through Installer Menu before
operator will recognize alert system.
To enable Fire Department Override, take
following steps and see Figure 48 and Figure 49:
1. Connect the NO contact from the alert system
or key switch to the following Smart DC
Controller terminals: EMERG OPEN and +24V.
2. Congure the Installer Menu. At a gate status
display, press the MENU button twice. This
accesses the User Menu and the CLOSE TIMER
display appears.
3. Simultaneously, press the OPEN and RESET
buttons to enter the Installer Menu. Release
the buttons and the USAGE CLASS display
appears. It is the rst item in the Installer Menu.
4. Press NEXT until the FIRE DEPARTMENT
OPEN display appears. The factory default
setting is 0.
5. Use the NEXT button to change the number
on the display to 1 and then press SELECT.
6. To exit the Installer Menu, press the MENU
button. The Gate status appears in display
indicating you have returned to Run Mode.
Figure 48. Fire Department Override Wiring
COM
STOP
OPEN
RADIO
CLOSE
OPEN
OPEN
PARTIAL
EYE
OPEN
EYE
CLOSE
EXIT
LOOP
BLOCK
EXIT
IN OBS
LOOP
OUT OBS
LOOP
CENTER
LOOP
EDGE
EYE
COM
+ 24 V
EMERG
OPEN
SHOW
LEDs
FIRE
Figure 49. Fire Department Override Commands
CT 0 (OFF)
CLOSE TIMER
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
HYSECURITY
GATE CLOSED
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
1. Start at a gate
status display.
2. To access the
User Menu,
press the MENU
button twice.
3. Access the
Installer Menu, by
simultaneously,
pressing the
OPEN and
RESET
buttons.
4. Use NEXT to
navigate to the
menu display.
Change the
setting using the
SELECT and
NEXT buttons.
FO 1
FIRE DEPT OPEN
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
LL 0 (OFF)
LEARN LIMIT
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT