DISPLAY AND MENU OPTIONS
Table 10. Smart DC Controller - Installer Menu Functions
Ref.
No.
User Menu
Display
Setting Options
(Bold = Factory
Settings)
Menu Tasks and Explanations
Associated
DC
Controller
Display
Connections
1
LL 0
LEARN LIMITS
0 = Normal
operation
1 = Reset limits
A setting of 1 places operator into
its learn limits mode which allows
you to reset gate’s open and close
positions. Refer to "Resetting the
OPEN and CLOSE Limits" on page
48.
Not applicable
(N/A)
2
UC 0
USAGE CLASS
0 = Gate disabled
1 = Residential 1 to
4 units
2 = Comm./public
access
3 = Light industria
4 = Industrial secure
Assign operator’s Usage Class
designation per UL 325 standards.
See
Identifying Gate Operator
Category and Usage Class on page
16
. The installer must designate
a usage class before operator will
function. See "Programming the
Initial Setup Menu" on page 23.
(N/A)
3
SH 0
GATE HANDING
0 = Gate disabled
R = Right hand
L = Left hand
Handing determines which way
gate opens as you view it from
operator side. If gate handing is
changed after initial setup, operator
resets limits. LEARN OPEN display
appears when you exit Installer
Menu. See "Programming the
Initial Setup Menu" on page 23.
(N/A)
4
WT 0
GATE WEIGHT (LB)
0 = Gate disabled 1,
2, 3, or 4 Gate weight
selections appear in
pounds. See "Table
3. Programming
Initial Setup Menu"
on page 24.
Select gate's weight range in
pounds. Correct gate weight allows
operator to determine appropriate
acceleration and deceleration
rates. See "Programming the Initial
Setup Menu" on page 23.
(N/A)
5
OS 1
OPEN SPEED
OT 17
0 = 0.75 ft/s
1 = 1.00 ft/s
2 = 1.25 ft/s
Designate how quickly gate opens:
0.75 ft/s − 1.25 ft/s. Setting of 2
reserved for Usage Class 3 and 4.
(N/A)
6
CS 1
CLOSE SPEED
OT 17
0 = 0.75 ft/s
1 = 1.00 ft/s
2 = 1.25 ft/s
Designate how quickly gate closes:
0.75 ft/s − 1.25 ft/s. Setting of 2
reserved for Usage Class 3 and 4.
(N/A)
SlideSmart HD Programming and Operations
5454
support.hysecurity.com