INSTALLING A LOCK FOR 12VDC OR
24VDC SYSTEMS
To install a lock for 12VDC or 24VDC systems, take
the following steps:
1. Connect a wire between COM on USER 1
RELAY and a COM terminal on the Smart DC
Controller board. See Figure 60.
Figure 60. Lock Installation 12/24 VDC
2. Connect the power lead from the lock to
the appropriate power spade (+24VDC or
+12VDC)
3. Connect the common wire from the lock to
NC on USER 1 RELAY if it is a maglock or NO
if it is a solenoid.
4. Set the User Relay function in the Installer
Menu to RL1 - 6. See Figure 62.
COM
COM
COM
COM
COM
COM
COM
COM
STOP
OPEN
RADIO
CLOSE
OPEN
SENSOR
2
SENSOR
3
SENSOR
3
EXIT
LOOP
OPEN
PARTIAL
BLOCK
EXIT
IN OBS
LOOP
OUT OBS
LOOP
CENTER
LOOP
SENSOR
COM
+ 24 V
EMERG
OPEN
SHOW
LEDs
U
S
ER2
COM
N
O
DC
USER 1 RELAY
NO
NC
COM
24VDC
24VDC
12VDC
12VDC
Aach the power wire from the lock
to the appropriate power spade.
Connect COM on board
to COM on USER 1 RELAY.
Connect the COM wire from
the lock.
A Solenoid lock aaches to NO.
A MagLock aaches to NC.
COM
DUAL GATE
RADIO OPTIONS
A
B
COM
OPEN
+24V
S1
RS485
RS485
1
2
3
SENSOR AND ACCESSORY CONNECTIONS
INSTALLING A LOCK FOR HIGH VOLTAGE
SYSTEMS
To install a lock on higher voltage systems (115V
or 230V), take the following steps:
1. Connect one lead of the power supply to one
lead of the lock’s coil. See Figure 61.
Figure 61. Lock Installation- High Voltage
2. Connect the other lead of the lock’s coil to NO
on USER 1 RELAY.
3. Connect the COM on USER 1 RELAY to the
second lead wire in the power supply (115V
or 230V).
4. Set the User Relay function in the Installer
Menu to RL1 - 6.
See Figure 62.
High voltage
High voltage
230VAC
Lock
USER 1 RELAY
NO
COM
POWER SUPPLY
1
2
3
NOTICE
Connect to NC on USER 1 RELAY if installing
a maglock.
SlideSmart HD Programming and Operations
8282