DISPLAY AND MENU OPTIONS
RESETTING THE OPEN AND CLOSE LIMITS
On occasion, the open and close limits may need
to be ne-tuned. Resetting the open and close
limits is easily accomplished by accessing the
Installer Menu. Examples where resetting the
limits is necessary, include:
z Replacing the chain or adjusting the chain to
the point where it affects the open and close
positions
z Removing or replacing the target magnet
z Setting the LEARN LIMITS display to 1 (erases
the open and close target positions from
memory).
To re-learn limits, take the following steps and
see Figure 42:
1. At a gate status display, press the MENU button
twice. The CLOSE TIMER display appears.
2. Simultaneously, press the OPEN and RESET
buttons to enter the Installer Menu. Release
the buttons and the LEARN LIMITS display
appears. It is the rst item in the Installer Menu.
3. Press SELECT, and then NEXT to change the
setting to 1. Press SELECT again. LEARN
OPEN ashes on the display indicating that
operator is ready to relearn the open limit.
4. Hold the OPEN button until the gate reaches
the desired open limit. Release the OPEN
button. (Note that if you go too far, you can
press CLOSE to reverse direction.)
5. Press STOP twice to preserve the open stop
location. LEARN CLOSE appears on the
display.
6. Hold the CLOSE button until the gate slides
to full close. Release the CLOSE button (Note
that if you go too far, you can press OPEN to
reverse direction.)
7. Press STOP twice. The full close stop is
retained in memory. For more information,
refer to "Establishing the Open & Close Limits"
on page 25.
8. An ALERT 15 message appears on the
display. To clear the alert, perform a full cycle
so the software recognizes the target. Press
OPEN, and then CLOSE. The gate will stop
automatically on the close cycle when it
reaches the programmed limit. As the target
magnet passes the sensor, the operator beeps
and the ALERT 15 message is cleared.
Figure 42. Resetting OPEN and CLOSE Limits
NOTICE
Do not set limits at the physical OPEN and
CLOSE stops. Leave a 1 to 2-inch (2.5 - 5cm)
gap to allow for minimal drift.
CT 0 (OFF)
CLOSE TIMER
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
HYSECURITY
GATE CLOSED
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
1. Start at a gate
status display.
2. To access the
User Menu,
press the MENU
button twice.
3. Access the
Installer Menu, by
simultaneously,
pressing the
OPEN and
RESET
buttons.
4. Press SELECT
and change the
setting to 1 using
the NEXT button.
Press SELECT
again. The
LEARN OPEN
display appears.
Refer to steps 4
through 8.
LL 0 (OFF)
LEARN LIMIT
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
LL 1 (ON)
LEARN LIMIT
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT