Spare Input and Spare Output Tables
Manual # 42-02-1P28 A3 5-35
5
HC Hall Call
HCF Hall Call Front
HCT Hall Call Time. Defined time for doors to remain open @ CAR DIAG > Door Dwell Timers
HDB
From ON position of switch used to bypass hoistway doors. Also places car on inspection
simultaneously. Hoistway Door Bypass signal to Safety Processor B @ MOTION DIAG >
MOTION Inputs
HDBO
From OFF position of switch used to bypass hoistway doors. Used for monitoring switch
Hoistway Door Bypass Off @ MOTION DIAG > MOTION Inputs
HDBOB
From OFF position of switch used to bypass hoistway doors. Used for monitoring switch
Hoistway Door Bypass OFF B @ MOTION DIAG > MOTION Inputs
ICEN In Car Inspection Enable @ System IO > System Inputs
ICPD In Car Inspection push button down @ System IO > System Inputs
ICPU In Car Inspection push button up @ System IO > System Inputs
ICTD Inspection Cartop down button @ System IO > System Inputs
ICTU Inspection Cartop up button @ System IO > System Inputs
IN1H
Programmable 24VDC active high input. Seismic (SS) or Counterweight (EQH) input. See
Job prints @ GROUP DIAG > GROUP inputs
IN2H
Programmable 24VDC active high input. Seismic (SS) or Counterweight (EQH) input. See
Job prints @ GROUP DIAG > GROUP inputs.
INA Inspection, Access. Hoistway access enable switch input @ System IO > System Inputs
INCP Inspection Car Panel @ System IO > System Inputs
INCT Inspection, Car Top @ System IO > System Inputs
IND Independent service input, @ SYSTEM IO > PROGRAMMED Inputs
LLI Light Load Input. Input from load weigher @ System IO > Programmable Inputs
LOT Lobby Open Dwell Time. Defined time for doors to remain @ CAR DIAG > Door Dwell Times
MC-CPI-2 The serial car panel interface board normally used to convert car panel signals to serial
MEB3 4 Monitor of solid state driver for EB3/4 @ MOTION DIAG > MOTION Inputs (Car Stop Bypass)
MLT Motor Limit Timer (Anti-Stall) @ ACTION INFO > Prohibit Run/Start Due to
MAIN CLOCK Main Clock @ PLDDIAG > PLD Inputs
MPME Monitor for PME solid state driver for UP Fast valve @ PLD DIAG > PLD Inputs
MPSBR
MPSBR is used by HAPS to signal the controller to lower the car. MPSBR can be found on
page 3 of System Inputs
MRDN Machine Room DOWN (inspection direction button) @ PLD DIAG > PLD Inputs
MREN Machine Room Enable (inspection enable button) @ PLD DIAG > PLD Inputs
MRIN Machine Room Inspection @ PLD DIAG > PLD Inputs
MRUP Machine Room UP (inspection direction button) @ PLD DIAG > PLD Inputs
NDF Nudging Function (signal) @GROUP DIAG > GROUP Outputs
NUDG Nudging (door closing) @ SYSTEM DIAG > Door control
PFG Passing Floor Gong @ System IO > Programmable Outputs, see FLR GONG flag
PHE Photo eye protection device for elevator car doors @ SYSTEM DIAG > Door Control
PLD Programmable Logic Device
PME.B Primary Output to pick Up Fast valve by MOTION @ MOTION DIAG > MOTION Outputs
PME.P Primary Output to pick Up Fast valve by PLD @ PLD DIAG > PLD Outputs
PMP Primary Motor Contactor Proving @ PLD DIAG > PLD Inputs - not used on Hydro controllers
PTI Power Transfer Input. Use to shut down the elevator @ System IO > Programmable Inputs
Table 5.5 Acronym Descriptions and Memory Locations