Final Adjustment
4-10 Manual # 42-02-1P28 A3
Final Adjustments on Normal Operation
The following final adjustments should be performed with the elevator operating on Normal
operation.
•Place the CONTROLLER TEST SW on the HC-CTL-2 board in the NORM position.
•MACHINE ROOM INSPECTION MODE switch on the HC-CTL-2 board in the NORM
position.
Place the Independent Service switch in the OFF position.
Verify that the LCD display indicates NORMAL.
Hall Calls
Place hall calls for all of the landings and make sure that all hall calls function properly.
Ride and Performance
Run the car to all stops:
Verify car call assignments.
Check for overshoot.
Verify door operation at all floors.
Check for proper ride quality.
Recheck
Recheck the operation of the following on Normal operation:
•Doors
•Car calls
Hall calls
•PIs
•Gongs and Lanterns
•Photo eye
Safety edge
Door open button
Options
Verify the operation of the following options: Independent Service, Fire Return Phase 1 (Main
Floor and Alternate Floor operation, if provided), Fire Phase II In-Car operation, and any other
options provided.