Specifications
Manual # 42-02-1P28 A3 1-17
CFSS Phase II (In-Car) Mode
CFSS Phase II should initiate after the elevator has arrived at the recall floor. The hospital staff,
or VIP can then take control of the car and go non-stop to their desired floor. The car can go
into CFSS Phase II automatically or be configured to wait for a momentary or constant pressure
key switch (CFSS II SW input). (See CONFIG 3 > CFSS for a full list of options).
Recall Switch Mode
• Motion 2000 TS provides four car recall inputs, Recall S1-S4.
• Each of the four recall switches can be configured to determine the car behavior when the
switch is activated. (See CONFIG 3 > RECALL SWITCHES for a full list of options).
Independent Service Mode
When independent service is initiated, all existing car calls are immediately canceled, and the
elevator is removed from hall call service. With the car stopped in a door zone, if car doors are
open, they will remain open; if closed, they will remain closed. During independent service the
car is controlled by car calls placed while independent service is active.
Upon arriving at a call, the elevator doors open and will remain open until the attendant closes
the doors using constant pressure on the door close button or on a car call button. Hall and
jamb mounted arrival fixtures are inoperative.
In this mode:
• Doors open automatically when the car is stopped in a door zone
• The operator presses and holds the door close button to close doors
• The operator chooses direction and initiates the run by placing car calls (first placed deter-
mines direction of run).
• The elevator will level into destination floors automatically and open its doors.
• Hall arrival lanterns or jamb mounted arrival lanterns are inoperative.
Mode Entry
• Call the car to a floor.
• Enter the car and activate the Independent mode key switch (IND input HC-CTL-2 board).