The Computer
5-44 Manual # 42-02-1P28 A3
CPI-2 Configuration
The CPI-2 boards in your controller are factory-configured to match the job requirements.
•Jumpers:
•JP1: Factory
• JP2: Used to terminate the CAN communication bus. If you have just one CPI-2 board,
this jumper should always be in the ON position. If you have more than one CPI-2
board, use this jumper on the last board in the string only.
• JP3: Sets the inactive level (OV or 24V) for the 24V INPUTS ONLY connections.
• 24V: OFF state is 24V. ON state is 0V. (USE FOR MOTION 2000 TS APPLICA-
TIONS.)
• 0V: Off state is 0V. ON state is 24V.
24V is the maximum input that may be applied. For outputs, 24V, 6W is the maximum load
supported.
•DIP Switch SW1, Board address switches: Four-position DIP switch SW1 provides a
unique address for each CPI board (you should never have two CPI boards with the same
SW1 setting).
• SW1, switch 3, must remain OFF at all times.
• SW1, switch 4, determines CAN baud rate:
• ON: 500k - used if board is mounted INSIDE the Motion 2000 TS controller cabinet
• OFF: 250k - default setting; use with boards mounted in COP
Installation and Connections Please refer to “Settings and Jumpers” on page 3-4.
SC-3HN Serial Hall Call Node Board
Please refer to “Hall Calls” on page 4-10 for a detailed description.
DIP 1 CPI Boards
Board SW1 SW2 SW3
0 Off Off Off
1 On Off Off
2 Off On Off
3 On On Off