The Computer
5-52 Manual # 42-02-1P28 A3
CFG ERR: INVALID FLOOR (323) Description: An invalid floor has been programmed.
CFG ERR: LAND SYS (324) Description: Configured and actual landing system do not match.
CFSS BYPASS TIMING (848) Description: The car has been assigned a CFSS call but CFSS operation is
currently bypassed due to the car being on Attendant or Independent ser-
vice. The car will answer the CFSS call when the current mode of operation
(ATS/IND) related timer(s) has expired or if the car is returned to normal
operation prior to the timer expiring.
Car actions: If the car is on Attendant or Independent service when it is
assigned a CFSS call, it shall remain under the current mode of operation
and start the mode’s related timer. The CFSS light indicator shall come on
to indicate to the attendant that the car is needed for a medical emergency.
The car will proceed to answer the CSS call upon expiration of the timer.
Troubleshooting:
1. Check and set the related CFSS BYPASS IND TIMER and CFSS
BYPASS ATS TIMER options.
2. Set the timer(s) to 0 if a car on IND or ATS is not eligible to take CFSS
calls.
CFSS RECALL (772) Commandeer for Special Service (Hospital Service) – Car has been selected
to answer a hospital call and is recalling to the floor the call was made.
CFSS IN-CAR (773) Commandeer for Special Service (Hospital Service) - Car has picked up
special passengers and is now under control of the passenger. Car will not
answer hall calls during this mode.
COMMERCIAL POWER LOSS (279) Description: Appears in the event log if commercial power is lost. Infor-
mational.
COMM & ALIVE INPUT LOW (284) Duplex Operation – Dispatching car has communication with the duplexed
car, but it is showing that is not powered.
Troubleshooting:
Check that the Alive inputs on both cars are wired to print and have volt-
age.
COMPLIANCE TEST ACTIVE (316) Description: A compliance/safety test has been initiated but is not yet
completed.
Troubleshooting:
1. Complete or abort the test.
CONSTRUCTION INVALID (96) Description: The car is in construction operation but controller switches or
inputs are in states not valid in construction operation. If stopped, the car
will not leave the floor. If in motion, the car will stop at the next floor and
shut down. The fault must be manually cleared before operation resumes.
Cannot be bypassed.
System Verifies: - Mode of Operation = Construction Invalid
Troubleshooting:
To exit construction operation see Set Up for Construction Operation on
page 3-4.
Table 5.10 Touch Screen Event Listings
Event Description