Specifications
Manual # 42-02-1P28 A3 1-11
FAULTS BYPASS: Each fault or event lists which fault bypass operating modes will prevent that
fault. Construction blocks the greatest number of faults, Inspection next, then Automatic. Auto-
matic mode fault bypass is on a two hour timer.
Inspection Operation Cartop inspection
Car panel inspection
Hoistway access inspection
Machine room inspection
Construction Fault Bypass Faults bypassed operation using run box or inspection controls. See
Faults Bypass note.
Inspection Fault Bypass Faults bypassed operation using inspection controls. See Faults Bypass
note.
Automatic Fault Bypass Faults bypassed operation in Automatic mode. See Faults Bypass note.
Emergency Operation Fire service (ASME A17.1/CSA B44)
NYC Appendix K
Massachusetts (2004 or 2013)
Earthquake Operation ASME A17.1/CSA B44
Seismic detection
Hall Call Loss
(Emergency Dispatch)
See page 1-20. May be initiated by input if programmed.
Flood Pit Flood (access blocking to one or more lower floors only)
Emergency Power MCE HAPS battery lowering option, building generator I/O standard
Load Response
(discrete load weigher
only)
Light load
Heavy load/Lobby departure
Standard overload
Fire Phase 2 overload (ANSI A17.1/CSA B44)
Anti-Nuisance Car call cancel on direction reversal
Cancel car calls behind car
Photo eye/designated number of stops car call cancellation
Load weigher/designated number of stops car call cancellation
Oil pressure, oil viscosity,
thermal overload
Condition must be corrected before car can return to service.
Table 1.3 Operating Modes