Fill Area: 4. Rectangle Band
This command lls a rectangular band area by moving the tip along a square, spiral-shaped path from the outside of the rectangle
to the center. After entering a Fill Area Rectangle Band command, enter a Line Start point at the top left corner of the area to be
lled and a Line End point at the bottom right corner of that area.
Line Start
Line End
EXAMPLE: If a Width of 5 mm and a Band of 15 mm are entered, the tip makes the following path:
Band = 15 mm
Width = 5 mm
Fill Area: 5. Circle Band
This command lls a dened circular band area by moving the tip along a spiral path from the outside of the circle to the center.
After entering a Fill Area Circle Band command, jog the tip to a point on the outside limit of the circle to be lled and enter that
location as a Line Start point. Then jog the tip directly across to the center of the circle and enter that location as a Line End point.
Line EndLine Start
Fill Area
EXAMPLE: If a Width of 5 mm and a Band of 15 mm are entered, the tip makes the following path:
Band = 15 mm
Width = 5 mm