107
Fig.98-VGMALT2
Fig.97-VGMALT1
• A (< 2 sec) to access ALTs
• S (< 2 sec) to acknowledge alarms
• S (2 sec) to access Compass
• M (2 sec) to access Gas Switching (or Bud Press Check)
• L (closure) to activate Backlight
VGM Alt 1, information includes (Fig. 97) -
> Max Depth as 3 dashes ( - - - ) with MAX and FT (or M)
icons
> Graphic EDT with Elapsed Dive Time (hr:min)
> Graphic FO2 with Set Point for Gas in use
> Graphic PO2 with current value (ATA), if Nitrox
> Nx icon, if Nitrox
• A (< 2 sec) to access ALT 2
• Revert to Main in 5 sec, if A not pressed
VGM Alt 2, information includes (Fig. 98) -
> Time of Day (hr:min sec), with A (or P) if 12 Hour
> Temperature with ° icon and graphic F (or C)
• 5 sec or A (< 2 sec), revert to Main