1 - 14
Chapter 1 Troubleshooting
016 754 PDF LZW Not Installed
Without installing “Contents Bridge Extension kit”, the PDF file
which is LZW compressed is processed by using PDF Bridge.
Open PDF file by using Adobe Acrobat Reader, and execute printing
from [Print] under [File].
Install Contents Bridge Extension kit.
-
016 755 PDF Print Prohibited
Print the PDF file which is specified not to print. Release the setting not
to print the PDF file by using Adobe Acrobat, and execute printing
again.
-
016 760 PS Decompose Error
When decomposing Post Script, an error is caused. Set [Print mode] to
[High quality]. When it is not recovered yet, set to [Normal].Add print
page buffer.Add PS use memory.
-
016 761 FIFO Empty ERR
Image extension error is caused. (FIFO Empty error)
Set [Print mode] to [High quality, and execute printing again.
When it is not recovered yet, set [page print mode] to [Yes].
-
016 762
Specified Decomposer
Not Exist
Unimplemented functions (printing language, printing utility, and so on)
are required.
The printer can print ART EX, ART Ⅳ , 201H, ESC/P, HP-GL, HPGL/2,
TIFF, and PDF data as standard.
If sending PostScript is expected, please install the optional PostScript
software kit.
-
016 796
Email Not Printed due to
User Settings
When printing attached files only at receiving e-mail is set, the e-mail
without attachment files is deleted.
When printing the message of the e-mail and e-mail header is
expected, change the setting on the property screen of CentreWare
Internet Services.
-
016 797
Invalid Output Destination
for Email Received
The address of the e-mail sent to this machine by using E-mail print
faction is not correct.
Specify the correct address, and resend the e-mail.
-
016 798 No TrustMarking Option
No HD error is returned when calling S-Image lib by Decomposer.
Install the required Option(HD).
-
016 799
Print Instruction Fail
detected in PLW
The combination of print parameters is not correct.
[Tray paper size] of trays 1-4 are set to [Auto] on the operation panel,
[Paper tray select] is set to [Auto], and print out in infinite form.
Check the printing indication.
-
016 982 -
When accessing HDD, detect Full status.
Detect the error that Full is not released even though it is waited for
while. (No page can be stored.)
After execute or delete the job (documents) in the same HDD partition,
execute the operation again.
103 203 Machine Code Fail
Machine Code is not set when shipping from the factory.
After the shipment, the data of Machine Code, or MCU PWB and ESS
PWB are replaced incorrectly.
Execute DC132 Serial No matching.
When it is not recovered yet, Replace ESS PWB or MCU PWB in
order. (Replacing both of them simultaneously is impossible.)
103 204 Serial No. Fail
Serial No. is not set when shipping from the factory.
After the shipment, the data of Serial No., or MCU PWB and ESS PWB
are replaced incorrectly.
Execute DC132 Serial No matching.
When it is not recovered yet, Replace ESS PWB or MCU PWB in
order. (Replacing both of them simultaneously is impossible.)
103 207
All Machine Codes
Mismatch
At least one of Product Codes which are maintained in three points are
wrong value.
Execute DC132 Serial No matching.
When it is not recovered yet, Replace ESS PWB or MCU PWB in
order. (Replacing both of them simultaneously is impossible.)
Chain Link Fault Items Conditions of detect/Methods of treatment Ref FIP