CHAPTER 12
| 86
FM MENU EXPERT MODE
The Attack speed and Release speed controls work in the same manner as their counterparts in the other sections of the
Omnia.9 , and the values are relative to the corresponding multiband attack/release speed slider.
The Comp Target controls set the target compression level for each band of the Dry Voice Detect AGC. A lower setting
provides less compression, while a higher setting provides additional compression. These controls have a range between
+18 and -3dB in one-quarter dB increments.
The Lim Target control sets the target output level of the Dry Voice AGC, again similar in operation to the other AGC sections
of the Omnia.9. A lower setting results in a lower output level, while higher settings provide a higher output level.