2-15
2 Basic System Configuration and Devices
CJ2 CPU Unit Hardware User’s Manual
2-1 Basic System Configuration
2
2-1-4 Configuration Units
Special I/O
Units
Temperature
Control Units
4 control loops, tem-
perature- resistance
thermometer inputs,
PNP outputs
CJ1W-TC102 20 words 200 words 0 to 94
(uses
words for
2 unit
numbers)
0.25 --- 150 g max.
2 control loops, tem-
perature-resistance
thermometer inputs,
NPN outputs, heater
burnout detection
CJ1W-TC103 20 words 200 words 0 to 94
(uses
words for
2 unit
numbers)
0.25 --- 150 g max.
2 control loops, tem-
perature-resistance
thermometer inputs,
PNP outputs, heater
burnout detection
CJ1W-TC104 20 words 200 words 0 to 94
(uses
words for
2 unit
numbers)
0.25 --- 150 g max.
Position Con-
trol Units
1 axis, pulse output;
open collector output
CJ1W-NC113 10 words 100 words 0 to 95 0.25 --- 100 g max.
2 axes, pulse out-
puts; open collector
outputs
CJ1W-NC213 10 words 100 words 0 to 95 0.25 --- 100 g max.
4 axes, pulse out-
puts; open collector
outputs
CJ1W-NC413 20 words 200 words 0 to 94
(uses
words for
2 unit
numbers)
0.36 --- 150 g max.
1 axis, pulse output;
line driver output
CJ1W-NC133 10 words 100 words 0 to 95 0.25 --- 100 g max.
2 axes, pulse out-
puts; line driver out-
puts
CJ1W-NC233 10 words 100 words 0 to 95 0.25 --- 100 g max.
4 axes, pulse out-
puts; line driver out-
puts
CJ1W-NC433 20 words 200 words 0 to 94
(uses
words for
2 unit
numbers)
0.36 --- 150 g max.
Space Unit
*1
CJ1W-SP001 None None --- 0.56 --- 50 g max.
ID Sensor
Units
V600-series single-
head type
CJ1W-V600C11 10 words 100 words 0 to 95 0.26 0.12 120 g max.
V600-series two-
head type
CJ1W-V600C12 20 words 200 words 0 to 94
(uses
words for
2 unit
numbers)
0.32 0.24 130 g max.
V680-series single-
head type
CJ1W-V680C11 10 words 100 words 0 to 95 0.26 0.13 120 g max.
V680-series two-
head type
CJ1W-V680C12 20 words 200 words 0 to 94 0.32 0.26 130 g max.
High-speed
Counter Unit
Two-axis pulse input,
counting rate:
500 kcps max.,
line driver compatible
CJ1W-CT021 40 words 400 words 0 to 92
(uses
words for
4 unit
numbers)
0.28 --- 100 g max.
CompoNet
Master Unit
CompoNet remote
I/O: 2,048 words, 512
bits max.
CJ1W-CRM21 10 words 100 words 0 to 95 0.40 --- 130 g max.
Compo-
Bus/S Mas-
ter Units
CompoBus/S remote
I/O, 256 bits max.
CJ1W-SRM21 10 words or
20 words
None 0 to 95 or
0 to 94
0.15 ---
66 g max.
*2
Type Name Specifications Model
Number of
words allo-
cated (CIO
2000 to CIO
2959)
Number of
words allo-
cated
(D20000 to
D29599)
Unit No.
Current consump-
tion (A)
Weight
5 VDC 24 VDC