405
CQM1 Cycle Time and I/O Response Time Section 7-1
62 PRV High-speed counter 0 or pulse output from an output bit: 2.5
91.5 Designating output via word
117.4 Designating output via *DM
High-speed counters 1 and 2 or pulse output from ports 1 and 2:
229.3 Designating output via word (reading status)
249.3 Designating output via *DM (reading status)
229.8 Designating output via word
(reading range comparison results)
256.3 Designating output via *DM
(reading range comparison results)
Absolute high-speed counters 1 and 2:
226.3 Designating output via word (reading status)
253.3 Designating output via *DM (reading status)
227.8 Designating output via word
(reading range comparison results)
253.3 Designating output via *DM
(reading range comparison results)
Code Mnemonic ON execution
time (µs)
Conditions OFF execution
time (µs)