A - 17
Appendices
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User’s Manual
A-2 Parameter List
A
Vibration Suppression Function Parameters
Pn
No.
Name Setting Description
Default
setting
Unit
Setting
range
Cycle the
power
supply
200 Adaptive Filter
Selection
Set the operation of the adaptive filter. 0 0 to 4
0 Disabled
1 One filter enabled. Frequency limit
applied when enabled.
2 Two filters enabled. Frequency limit
applied when enabled.
3 One filter always enabled.
4 Two filters enabled, one of which is
always enabled.
201 Notch 1
Frequency
Setting
Set the notch frequency of the first resonance
suppression notch filter.
5,000 Hz 50 to
5,000
202 Notch 1 Width
Setting
Set the notch width of the first resonance
suppression notch filter.
2 0 to 20
203
Notch 1 Depth
Setting
Set the notch depth of the first resonance
suppression notch filter.
0 0 to 99
204 Notch 2
Frequency
Setting
Set the notch frequency of the second
resonance suppression notch filter.
5,000 Hz 50 to
5,000
205 Notch 2 Width
Setting
Set the notch width of the second resonance
suppression notch filter.
2 0 to 20
206
Notch 2 Depth
Setting
Set the notch depth of the second resonance
suppression notch filter.
0 0 to 99
207 Notch 3
Frequency
Setting
Set the notch frequency of the third resonance
suppression notch filter.
This parameter is automatically set when the
adaptive filter is enabled.
5,000 Hz 50 to
5,000
208 Notch 3 Width
Setting
Set the notch width of the third resonance
suppression notch filter.
This parameter is automatically set when the
adaptive filter is enabled.
2 0 to 20
209
Notch 3 Depth
Setting
Set the notch depth of the third resonance
suppression notch filter.
This parameter is automatically set when the
adaptive filter is enabled.
0 0 to 99
210 Notch 4
Frequency
Setting
Set the notch frequency of the fourth resonance
suppression notch filter.
This parameter is automatically set when the
adaptive filter is enabled.
5,000 Hz 50 to
5,000
211 Notch 4 Width
Setting
Set the notch width of the fourth resonance
suppression notch filter.
This parameter is automatically set when the
adaptive filter is enabled.
2 0 to 20
212
Notch 4 Depth
Setting
Set the notch depth of the fourth resonance
suppression notch filter.
This parameter is automatically set when the
adaptive filter is enabled.
0 0 to 99