5-28
n019 Acceleration Time 1 Register 0113
Hex
Changes during
operation
Yes
Setting
range
0.0 to 6,000 (s) (see note 1) Unit of
setting
0.1 s
(see
note 1)
Default setting 10.0
n020 Deceleration Time 1 Register 0114
Hex
Changes during
operation
Yes
Setting
range
0.0 to 6,000 (s) (see note 1) Unit of
setting
0.1 s
(see
note 1)
Default setting 10.0
n021 Acceleration Time 2 Register 0115
Hex
Changes during
operation
Yes
Setting
range
0.0 to 6,000 (s) (see note 1) Unit of
setting
0.1 s
(see
note 1)
Default setting 10.0
n022 Deceleration Time 2 Register 0116
Hex
Changes during
operation
Yes
Setting
range
0.0 to 6,000 (s) (see note 1) Unit of
setting
0.1 s
(see
note 1)
Default setting 10.0
Note 1. The setting unit of acceleration or deceleration time is determined by the set
value in n018 (acceleration/deceleration time unit).
n018 set to 0: Setting range from 0.0 to 6,000 (0.0 through 999.9 s or 1,000
through 6,000 s)
n018 set to 1: Setting range from 0.00 to 600.0 (0.0 through 99.99 s or 100.0
through 600.0 s)
Note 2. Whenn018 issetto1,thedefaultvalue ofaccelerationordecelerationtimewill
be set to 10.00.
H S-shape Acceleration/Deceleration Characteristic (n023)
·Trapezoidal and S-shape acceleration and deceleration are available. Using the
S-shapecharacteristicfunctionforacceleration and deceleration can reduce shock to
the machinery when stopping or starting.
·Any one of three S-shape acceleration/deceleration times (0.2, 0.5, and 1.0 s) is
selectable.
n023 S-shape Acceleration/
Deceleration Characteristic
Register 0117
Hex
Changes during
operation
No
Setting
range
0 to 3 Unit of
setting
1 Default setting 0