7-45
H Creating a Sequence
1. ClickonNew Protocolwiththeleftbuttonofthemouse.Thenclickonablankspace
with the right button of the mouse.
2. Select New Send & Recv Sequence.
The following table will appear. Set the parameters related to the sequence in the
table.
* # Send & Recv
sequence
Link word Transmis-
sion control
parameter
Response Timer Tr Timer
Tfr
Timer
Tfs
000 Inverter I/O
Send & Recv
--- Set (Setting
required)
Scan 0.5 0.5 0.5
#
Sequence number. The sequence number is automatically set.
Send & Recv Sequence
The label (name) of the sequence. Input an appropriate, easy-to-distinguish name.
Link Word
Set the area for sharing the data between the Programmable Controller and Commu-
nications Board.
Note Inthisexample,thelinkwordisspecifiedbytheoperandofthePMCRinstruction.
Therefore, no link word is set here.
Transmission Control Parameter
Set the control method, such as flow control.
Note Select only model control for communications with the 3G3MV.
Response
A method to write reception data to the I/O memory of the Programmable Controller.
Note Select “notify by scan” for communications with the 3G3MV.
Communications Chapter 7