2-44
D Connecting a Motor to the Inverter
·When connecting a motor tothe Inverter, be sure touse a cable with abraided shield.
·Reduce the length of the cable as short as possible and ground the shield on the
Inverter side as well as the motor side. Furthermore, it is recommended that a clamp
core (Clamp Filter) be connected close to the output terminals of the Inverter.
Product Model Manufacturer
Clamp Filter 3G3IV--PFO OC2 RASMI
D Wiring a Control Cable
·Be sure to connect a cable with a braided shield to the control circuit terminals.
·Ground the shield on the Inverter side only.
D Grounding the Shield
In order to ground theshield securely, it isrecommended thata cable clampbedirectly
connected to the ground plate as shown below.
Ground plate
Cable clamp
Cable
Shield
Design Chapter 2