Connecting to the CX-Programmer Version 2.1 or Lower Section 3-8
75
5. Change the settings of [Network] and [Node] for [FINS Destination Ad-
dress] to the network address and the node address for the FINS address
displayed in the Guide to Connect.
• The routing table for FinsGateway must be changed if the Network address
is to be changed.
1. Do not change the unit address for the FinsGateway Communications Unit
with FinsGateway setting tool, etc. Changing the unit address may cause
the [Connect] operation to fail.
2. Do not set items to the local network table when setting the routing table to
the CX-Simulator. The local network table will automatically be changed
when [Connect] is executed. If communications with the Ladder Engine
can not be executed after setting the routing table, [Disconnect] and then
[Connect] again.
Note
3. If a new FinsGateway Communications Unit with the same name is started
by the FinsGateway service manager, etc. during [Connect], the new unit
will fail to start. The Communications Unit with the same name can not be
used simultaneously.
4. For instructions on changing the routing tables, refer to Section 3 of the
CX-Integrator Operation Manual (W445).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron WS02-SIMC1-E - V1.9 REV 02-2009 and is the answer not in the manual?

Omron WS02-SIMC1-E - V1.9 REV 02-2009 Specifications

General IconGeneral
BrandOmron
ModelWS02-SIMC1-E - V1.9 REV 02-2009
CategorySoftware
LanguageEnglish

Related product manuals