Generating Virtual External Inputs Section 8-3
164
List of Usable FINS Command Filters and Data Replay Possible/Not possible
Access IOM area
MR SR FINS Command Replay possible
01 01 Read IOM area Not possible
01 02 Write IOM area Possible
01 03 Write all IOM area Possible
01 04 Read complex IOM areas Not possible
01 05 Transfer IOM area Possible
Access parameter area
MR SR FINS Command Replay possible
02 01 Read IOM area Not possible
02 02 Write IOM area Possible
02 03 Write all IOM area Possible
Execution controls
MR SR FINS Command Replay possible
04 01 Execution Controls (Start) Possible
04 02 Execution Controls (Stop) Possible
Access time info
MR SR FINS Command Replay possible
07 01 Read time info Not possible
07 02 Write time info Possible
Exchange messages
MR SR FINS Command Replay possible
09 20 Message read/cancel Possible
Maintenance
MR SR FINS Command Replay possible
21 01 Cancel Error Possible
21 02 Read Error log Not possible
21 03 Clear Error log Possible
Peripheral devices
MR SR FINS Command Replay possible
22 0A IOM areaFile transfer Possible
22 0B ParameterFile transfer Possible
22 0C IN-UMFile transfer Possible
Debugging
MR SR FINS Command Replay possible
23 01 Force set/reset Possible
23 02 Cancel All Forces Possible

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron WS02-SIMC1-E - V1.9 REV 02-2009 and is the answer not in the manual?

Omron WS02-SIMC1-E - V1.9 REV 02-2009 Specifications

General IconGeneral
BrandOmron
ModelWS02-SIMC1-E - V1.9 REV 02-2009
CategorySoftware
LanguageEnglish

Related product manuals