Error Processing Section 10-1
241
Symptoms Causes Remedies
Failed to start FinsGateway.
FinsGateway may have been
installed incorrectly or the set-
tings are invalid.
Wrong execution
environment.
Re-install the CX-Programmer and the CX-Server, or
FinsGateway.
Failed to start I/O Condition Tool. Poor resource for
executing or
wrong execution
environment.
1. Exit executing application programs excluding the
CX-Simulator and try again.
2. Uninstall and then reinstall the CX-Simulator.
Failed to start Log display appli-
cation.
Wrong execution
environment.
1. Exit executing application programs excluding the
CX-Simulator and try again.
2. Uninstall and then reinstall the CX-Simulator.
Failed to start the Alarms display
application.
Wrong environ-
ment for the
Alarms display
application.
The event viewer is not working for Windows NT and
the memo pad for Windows95/98. Change the OS
settings so as to work.
Failed to start Virtual Communi-
cations Unit.
Wrong execution
environment.
Uninstall and then reinstall the CX-Simulator.
Failed to switch the current UM.
Failed to gain the access rights of
CX-Simulator Ladder Engine.
Another applica-
tion program is
writing to the UM.
After the application program being writing is com-
pleted, try again.
The node address of FinsGate-
way -- unit is duplicated. Change
the node address of FinsGateway
communications unit to start.
1. Change the FINS node address of the commu-
nications path in the [Work CX-Simulator] win-
dow.
2. Change the duplicated node address using net-
work communications setting.
The program is running. Cannot
set a start point.
Tried to set a start
point while running
the program.
A start point can be set only when stopping (Program
mode).
Unable to allocate the network
number since the number of
registered network in the Fins-
Gateway routing table is maxi-
mum. Delete the unused network
then reconnect.
Reset the routing table using the CX-Integrator.
Unexecuted Cyclic task cannot
be changed to WAIT mode.
Tried to change a
Cyclic task in INI to
WAIT mode.
Try again after executing the program.
Unit profile does not exist or the
file format is invalid.
Wrong execution
environment.
Uninstall and then reinstall the CX-Simulator.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron WS02-SIMC1-E - V1.9 REV 02-2009 and is the answer not in the manual?

Omron WS02-SIMC1-E - V1.9 REV 02-2009 Specifications

General IconGeneral
BrandOmron
ModelWS02-SIMC1-E - V1.9 REV 02-2009
CategorySoftware
LanguageEnglish

Related product manuals