Functions of Unit and Restrictions on Combination
1-4
1.2 Restrictions on Combinations and Functions
1.2.1 Applicable Versions of Unit and Software
For using FP0H, the software of the following versions is necessary.
Item
Applicable versions
Programming Software
Control FPWIN GR7
FPWIN GR7 Ver.2.19 or later
Configurator PMX
It is used for using the pulse output function in the table setting mode. It is
implemented in FPWIN GR7/Pro7 and activated from the option menu.
Programming Software
Control FPWIN Pro7
FPWIN PRO7 Ver.7.2.0 or later
(Note 1): The latest version is provided free of charge at our website
http://industrial.panasonic.com/ac/e/dl_center/software/
Use the latest version.
(Note 2): It is also necessary to install a setup file for using FP0H with FPWIN Pro7. For details, see the above
website.
1.2.2 Restrictions on I/O Allocation
I/O signals used for each function are set in the tool software. They are allocated
automatically when set by Configurator PMX.
Allocate the I/O numbers used for the pulse output function, high-speed counter function and
PWM function so that they do not overlap.
Examples of unusable combinations
Example
When using the output Y0 as CH0 for the pulse output function, the PWM output CH0 cannot be
used.