Specifications
12-10
12.3.2 Common area (Memory Area No. 0)
●: Available, -: Not available
0000 Axis setting H0
Stores used channels (axes) and usage methods.
Monitor using binary display.
bit no. Settings
0
Not use CH0 (0) / Use CH0 (1)
1
Not use CH1 (0) / Use CH1 (1)
2
Not use CH2 (0) / Use CH2 (1)
3 Not use CH3 (0) / Use CH3 (1)
4-7 Disable the setting
8
As interpolation axis,
Not use CH0/CH1 (0) / Use
CH0/CH1 (1)
9
As interpolation axis,
Not use CH2/CH3 (0) / Use
CH2/CH3
10-15
Disable the setting
0001
Positioning repeat count
(CH0)
K0
Stores the repeat count in decimal when using the
repeat control in the position control.
Set value Operation
0 or 1 Not repeat an operation.
2-254
Repeat an operation for a
specified number of times.
255 or
more
Repeat an operation infinitely.
0002
Positioning repeat count
(CH1)
K0
0003
Positioning repeat count
(CH2)
K0
0004
Positioning repeat count
(CH3)
K0
Reserved for system - - - -
0007
Error code
H0
Stores a generated positioning error code in Hex
format (hexadecimal) when using the pulse output
function (table setting mode).
The higher 8 bits indicate channel number.
The lower 8 bits indicate error code.
-
Reserved for system
-
-
- -