11.1 FP Mode
11-3
Item
Specifications
Conventional
model
FP
Σ
series
FP0H series
FP
Σ
mode
FP0H mode
Values in [ ] are for
C32E only.
Potentiometer input
(DT90040/90041)
K0 to K1000 K0 to K1000 (C32 only) K0 to K4000 (C32 only)
High-speed counter/Pulse
output
(Note 1)
4 chs / 2 chs
The same area is used
for both special relays
and special data
registers.
4 chs / 2 chs
The same area is used
for both special relays
and special data
registers.
4chs / 4 chs
The used areas for
special relays and
special data registers
are independent.
(Note 1): For details of the high-speed counter/pulse output functions, refer to "FP0H User's Manual
(Positioning/PWM Output/High-speed Counter)".
11.1.2 Converting Projects for FPΣ to Projects for FP0H (FPΣ Mode)
Projects for the conventional model FPΣ can be converted to projects for FP0H (FPΣ) by
"Convert PLC Type" function. The following procedure is explained on the condition that a
project for FPΣ has been already started on FPWIN GR7.
PROCEDURE
1. Select "Tools" > "Convert PLC Type" in the menu bar.
2. Select "FP0H" from the list on the left.
3. Select "FP0HC32T/P" or "FP0H C32ET/EP" and press the [OK] button.
4. The "Convert PLC Type" function will be executed and projects for FP0H
will be converted to projects for FP0H.