10.4 High-speed Counter Cam Control Instruction
10-23
Sample program
For FP0H mode
R0
DF
R9013
F165 CAM0 DT100
H10 DT100F1 DMV
K1 DT102F1 DMV
K10 DT104F1 DMV
K2 DT106F1 DMV
K1000 DT108F1 DMV
K5000 DT110F1 DMV
K7000 DT112F1 DMV
K9000 DT114F1 DMV
K11000 DT116F1 DMV
K0 DT90300
F1 DMV
R9110
Code
Description
High-speed counter channel H10: Performs the upper limit control. CH0
Cam output device type K1: Internal relay (R)
Word number of cam output device K10
Specification of the number of target values K2
Target value 1: ON set value K1000
Target value 1: OFF set value K5000
Target value 2: ON set value K7000
Target value 2: OFF set value K9000
Upper limit value K11000
Presets 0 as the elapsed value.
Executes the F165 (CAM0) instruction and starts the cam control.
(Note): The allocations of control active flags and elapsed value areas for the FPΣ mode are different.