12.3 Positioning Memory
12-9
Reading from positioning memory
• It is possible to read the areas which are shown with "Available" in the "R" column in the
following table using the F384 (PTBLR) instruction in user programs during RUN. The
operand of the instruction is specified using the combination of an area number and offset
address.
Writing to positioning memory
• When the mode changes from PROG. to RUN, the contents set by the tool software
Configurator PMX will be stored.
• It is possible to rewrite the areas which are shown with "Available" in the "W" column in the
following table using the F385 (PTBLW) instruction in user programs during RUN. The
operand of the instruction is specified using the combination of an area number and offset
address.
• Be sure not to execute writing in the reserved areas for the system.