Value Range Max. 384 characters
Note
• If this URL ends with "/" (slash), "{MODEL}.cfg" is
automatically added at the end of the URL. For example,
CFG_PRODUCT_FILE_PATH="http://host/dir/"
becomes CFG_PRODUCT_FILE_PATH="http://host/
dir/{MODEL}.cfg".
• For details about the formats, see 2.1.3 Server Address
Formats.
Default Value Empty string
Web User Interface Reference Product File URL (Page 170)
CFG_MASTER_FILE_PATH
Value Format STRING
Description Specifies the URL of the master configuration file, which is used when
all units need the same settings.
Value Range Max. 384 characters
Note
• If this URL ends with "/" (slash), "sip.cfg" is automatically
added at the end of the URL. For example,
CFG_MASTER_FILE_PATH="http://host/dir/"
becomes CFG_MASTER_FILE_PATH="http://host/dir/
sip.cfg".
• For details about the formats, see 2.1.3 Server Address
Formats.
Default Value Empty string
Web User Interface Reference Master File URL (Page 171)
CFG_CYCLIC
Value Format BOOLEAN
Description Specifies whether the unit periodically checks for updates of
configuration files.
Value Range
• Y: Enable periodic synchronization
• N: Disable
Default Value
N
Web User Interface Reference Cyclic Auto Resync (Page 171)
Document Version 2017-07 Administrator Guide 221