RINGBACK_TONE_TIMING
Value Format Comma-separated Integer
Description Specifies the pattern, in milliseconds, of ringback tones using up to 10
whole numbers (off 1, on 1, off 2, on 2…) separated by commas.
Note
• It is recommended that you set a value of 60 milliseconds or
more for the first value (off 1).
Value Range 0–16000 (0: Continuous)
Note
• Avoid setting 1–50 for any of the values.
Default Value 60,2000,3940
Web User Interface Reference Tone Timings (Page 165)
HOLD_TONE_FRQ
Value Format Comma-separated Integer
Description Specifies the dual-tone frequencies, in hertz, of the hold tone using 2
whole numbers separated by a comma.
Value Range 0, 200–2000 (0: No tone)
Default Value 425
HOLD_TONE_GAIN
Value Format INTEGER
Description Specifies the gain, in decibels, of the hold tone.
Value Range -24–24 (dB)
Default Value 0
BELL_CORE_PATTERN1_TIMING
Value Format Comma-separated Integer
Description Specifies the cadence, in milliseconds, of pattern ID 1, described in the
LSSGR, GR-506-CORE, "Signaling for Analog Interfaces" section 14,
using up to 8 whole numbers (on 1, off 1, on 2, off 2…) separated by
commas.
Value Range 0–5000 (0: Continuous)
Note
• Avoid setting 1–50 for any of the values.
332 Administrator Guide Document Version 2017-07
5.3.31 Tone Settings