EasyManuals Logo

Parker SPD-N Series User Manual

Parker SPD-N Series
192 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #85 background imageLoading...
Page #85 background image
Parker Hannifin S.p.A. Divisione S.B.C. user’s manual TWIN-N and SPD-N
84
0 when the command has been enabled.
b150.14
Immediate electronic cam engaging. Command to engage the cam movement.
This bit is automatically set to 0 when the command has been enabled.
b150.15
Immediate electronic cam release. Command to release the cam movement
This bit is automatically set to 0 when the command has been enabled.
b180.0
Start Tab0 on master phase of Pr168:169. =1 activates the Tab0 table to the
specified phase master in Pr168:169. The values of the parameters for the
activation on specific phase must be comprised between 0 and the written
module master in Pr110:111.
b180.1
Start Tab1 on master phase of Pr170:171. =1 activates the Tab1 table to the
specified phase master in Pr170:171. The values of the parameters for the
activation on specific phase must be comprised between 0 and the written
module master in Pr110:111.
b180.2
Start Tab2 on master phase of Pr172:173.
=1 activates the Tab2 table to the
specified phase master in Pr172:173. The values of the parameters for the
activation on specific phase must be comprised between 0 and the written
module master in Pr110:111.
b180.3
Start Tab3 on master phase of Pr174:175. =1 activates the Tab3 table to the
specified phase master in Pr174:175. The values of the parameters for the
activation on specific phase must be comprised between 0 and the written
module master in Pr110:111.
b180.4
Start Tab.0. Immediate activation of Tab0. Show table activate in CAM1
generator.
b180.5
Start Tab.1. Immediate activation of Tab1. Show table activate in CAM1
generator.
b180.6
Start Tab.2. Immediate activation of Tab2. Show table activate in CAM1
generator.
b180.7
Start Tab.3. Immediate activation of Tab3. Show table activate in CAM1
generator.
b180.14
(0)Cought quota master frequency imput (1) Cought quota Motor position-
Storage in Pr58:59
b181.0
Enabled Tab.0 in the Cam. =1 Tab0 activates.
b181.1
Enabled Tab.1 in the Cam.
=1 Tab0 activates.
b181.2
Enabled Tab.2 in the Cam.
=1 Tab0 activates.
b181.3
Enabled Tab.3 in the Cam.
=1 Tab0 activates.
b181.8 Enable virtual table (Tab.3).
b181.12 Activation change value of the slave module in phase.